Technical data

Type approval n°
TÜV · WR 98-399

Input / Output
Interface for CAN bus to DIN ISO 11898 CANopen

Output – voltage supply for electrode
Power supply 24 V DC, short-circuit protected
4 volt-free relay contacts.
Max. contact rating with switching voltages of 24 V AC, 115 V AC and
230 V AC: 4 A resistive, 0.75 A inductive at cos

ϕ

0.5

Max. contact rating with a switching voltage of 24 V DC: 4 A.
Contact material: silver, hard-gold plated

Interference suppression
Provide contactor with an external RC combination (100

/ 47 nF)

Relay de-energizing delay
Output “

MIN

”, “

MAX

” 3 s

Indicators and adjustors
4 pushbuttons for parameterisation/"TEST"
1 red LED for switchpoint “

HIGH

LEVEL

” (MAX)

1 red LED for switchpoint “

LOW

LEVEL

” (MIN)

2 green LEDs for switchpoints “pump ON” and “pump OFF”
1 green LED “

POWER

1 red LED “

BUS

FAULT

1 ten-pole code switch, 7 poles for node ID and 3 poles for baud rate settings

Sensitivity
Range 1:

10 µS/cm

Range 2:

0.5 µS/cm

Supply voltage
230 V ± 10 %, 50/60 Hz
115 V ± 10 %, 50/60 Hz (option)

Power consumption
10 VA

Protection
Case:

IP 40 to DIN ISO 60529

Terminal strip: IP 20 to DIN ISO 60529

Admissible ambient temperature
0 °C to 55 °C

Enclosure material
Front panel: polycarbonate, grey
Case: polycarbonate, black

Weight
Approx. 0.8 kg