Installing to wall, Warning – Desa CGN10T User Manual

Page 10

Advertising
background image

10

102921

Figure 5 - Mounting Screw Locations

Mounting

Screw

Locations

8 7/8"

Minimum To

Maintain 6"

Clearance
From Wall

7 3/4"

20 1/4"

Minimum To

Maintain 3"

Clearance

From Floor

FLOOR

JOINING WALL

INSTALLING HEATER TO WALL

Marking Screw Locations

1. Determine where you will locate heater.

2. Mark two mounting screw locations on wall (see Figure 5).

INSTALLING TO

WALL

Continued

WARNING ICON

G 001

WARNING

Maintain minimum clearances shown in Figure 5. If you can,
provide greater clearances from floor and joining wall.

For convenience and efficiency, install heater

• where there is easy access for operation, inspection, and service
• in coldest part of room

Figure 4 - Mounting Clearances As Viewed From Front of Heater

36"

3"

FLOOR

CEILING

Minimum

Minimum To Top Surface
Of Carpeting, Tile Or Other
Combustible Material

6"

Minimum
From
Sides Of
Heater

Right
Side

Left
Side

THERMOSTAT SENSING BULB

The thermostat sensing bulb is located inside the heater. Do not move this bulb
during installation or operation of the heater.