102921

TECHNICAL

SERVICE

You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-
5190.

SPECIFICATIONS

When gas pressure is too low

• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat

When gas quality is bad

• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local natural gas supplier.

SERVICE

HINTS

CGN10T

Btu (Variable)

5,000/10,000

Type Gas

Natural Only

Ignition

Piezo

Pressure Regulator Setting

3" W.C.

Inlet Gas Pressure (inches of water)

Maximum

10.5"

Minimum

4"

Dimensions, Inches (H x W x D)

Heater (Including knobs and grill)

21 1/2 x 13 1/2 x 7

Carton

25 1/4 x 16 3/4 x 7 1/2

Weight (pounds)

Shipping

19