Fulgor Milano CH 1004 ID TS User Manual

Page 51

Advertising
background image

50

51

GB

Error code

description

Possible causes

Error recovery

C

The cooking zone can
be configured if a static
“C” is shown.

It’s not an error, the user
is in the serivice menu.

A suitably pan must be
placed on the relevant
cooking zone.

C/-

The cooking zone will be
configured if a blinking
“C” is shown. After a
successful configuration
the relevant display
shows “-”.
When the “-” is not
displayed please check
the possible causes of
the E/5.

The user is in the
service menue, it’s not
an error.

Wait for the sysmbol
“-” or abort the
configuratuib activities
by pressing the
selectkey and the “C”
does not blink anymore.

2. over voltage.

Exchange the module.

E/7

Non assignable faillure.

Exchange modul or User
Interface.

E/8

Fan faillure.

Fan or control electronic
is defect.

Exchange the modul.

E/9

Defect T sensor on
inductor.

Sensor signal out of
valid range; sensor or
electronic is defect.

Exchange the modul.

E/A

Hardware defect of
induction modul.

Defect hardware device
detected by the self
check of the modul.

Exchange the modul.

E/C

Configuration failure.

2 cooking zone are
dedicated to the same
element of the UI.

1. Erase the actual
configuration manual
with service menù.

E/H

Fixed sensor value (test
function for T sensor on
inductor).

Not enough temperature
change (10K) within 5
min after switch on the
hob.

Systerm must cool
down.

No functionality
and no displaying

Overvoltage on the
switch mode power
supply (jno fuctionality).

400V connection.

Disconnet and
correct the power line
connection.

E

A blinking “E” on each
cooking zone indicates,
that all configs will be.

The user is in the
service menù, it’s not an
error.

Manual configuration.

E/2
(Error code
different for some
UI)

Temperature limits are
excessed.

1. Pot or glas
temperature is to
2. NTC - electronik
temperature to high.

System must cool down.