Horizontal Termination Configurations

Figures 28 through 30 show different configurations for venting
with horizontal termination. Each figure includes a chart with
vertical minimum/maximum and horizontal maximum dimensions
which must be met. Seal all connections with high temperature
silicone sealant (outer pipe only) as specified in the second warning
statement on page 12. All horizontal piping runs require 1/4" rise per
12" of horizontal run.

Venting with Three 90

°

Elbows

Vertical (V) Horizontal (H

1

) Horizontal (H

1

) +

Horizontal (H

2

)

6' min.

4' max.

8' max.

7' min.

6' max.

12' max.

8' min.

8' min.

20' max.

20' max.

8' max.

20' max.

VENTING INSTALLATION

Continued

VENTING INSTALLATION

Installation for Horizontal Termination (Cont.)

Figure 30 - Horizontal Termination Configuration for Venting
Using Two 90

°

Elbows with Termination at 90

°

with Stove

Figure 28 - Horizontal Termination Configuration for Venting
Using One 90

°

Elbow

Horizontal Venting

Vertical (V) Horizontal (H)

52" min.

26" max.

63" min.

49" max.

86" min.

96" max.

91" min.

20' max.

Figure 29 - Horizontal Termination Configuration for Venting
Using Three 90

°

Elbows

Venting with Two 90

°

Elbows

Vertical (V)

Horizontal (H

1

) +

Horizontal (H

2

)

6' min.

4' max.

7' min.

6' max.

8' min.

10' max.

20' max.

12' max.