INSTALLATION

Continued

Figure 5 - Equipment Shutoff Valve

Equipment
Shutoff
Valve

Open

Closed

Figure 7 - Checking Gas Joints

(Natural Gas Only)

Control Valve
Location

Equipment
Shutoff Valve

Propane/LP
Supply Tank

Equipment
Shutoff Valve

Gas Meter

Figure 6 - Checking Gas Joints

(Propane/LP Gas Only)

Control Valve
Location

4. Check all joints of gas supply piping system.

Apply noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff

valve to gas supply. Check reconnected fit-

tings for leaks.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 5).
2. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas or opening main gas valve

located on or near gas meter for natural gas

or using compressed air.

3. Check all joints from gas meter to equipment

shutoff valve for natural gas or propane/LP

supply to equipment shutoff valve for propane/

LP (see Figure 6 or 7). Apply noncorrosive

leak detection fluid to all joints. Bubbles

forming show a leak.

4. Correct all leaks at once.

Gas Pressure Check
The appliance regulator controls the burner pres-

sure which should be checked at the pressure test

point (1/8" NPT plugged tap) located near the on

the control valve identified OUT for the manifold

side and IN for inlet pressure. Make sure operating

pressures are within the limits shown in Specifica-

tions, page 15.
The pressure should be checked with the unit

burning and set to High. Replace test point plug

or tighten test screw after pressure measurement

ensuring no gas leaks.

PLACEMENT OF FLOOR MEDIA

WARNING: Do not add ex-

tra logs or ornaments such as

pine cones, vermiculite or rock

wool. Using these added items

can cause sooting. Use only the

material included in the kits.

WARNING: Do not place lava

rock, embers or fiber log pieces on

logs or burners. This may cause

sooting. Place floor media material

only on the fireplace floor.

1. Place lava rock around base of unit making sure

the burner ports and valve access are not blocked

(see Figure 8, page 9). Retain a small amount of

lava rock to be used in step 4, page 9.

2. Place ember material around front and sides

of unit close to (but NOT on) the burner (see

Figure 9, page 9). Embers will "glow" when

heated to enhance the realistic look of your

log set.