Specifications, Wiring diagram – Desa HCA-24-RFN User Manual

Page 15

Advertising
background image

www.desatech.com

115481-01A

15

SPECIFICATIONS

HCA-24-RFN

HCA-24-RFP

HCA-18-RFN

HCA-18-RFP

HCM-24-RFN

HCM-24-RFP

HCM-18-RFN

HCM-18-RFP

HKE-24-RFN

HKE-24-RFP

HKE-18-RFN

HKE-18-RFP

Btu (Variable)

45,000/67,000

43,000/65,000

41,000/56,000

42,000/51,000

Type Gas

Natural Gas Only Propane/LP Only Natural Gas Only Propane/LP Only

Ignition

Piezo

Piezo

Piezo

Piezo

Manifold Pressure 3.5" - 1.6"W.C.

10" - 6.3"W.C.

3.5" - 1.6"W.C. 10" - 6.3"W.C.

Inlet Gas Pressure (in. of water)
Maximum

10.5" W.C.

13" W.C.

10.5" W.C.

13" W.C.

Minimum*

5.0" W.C.

11" W.C.

5.0" W.C.

11" W.C.

Valve Operation

RF Millivolt

RF Millivolt

RF Millivolt

RF Millivolt

Orifice Size

#21

#42

#28

#45

* For purpose of input adjustment

WIRING DIAGRAM

Outlet
Pressure
Tap

Inlet
Pressure
Tap

Piezo

Gas Control
Knob

Pilot
Adjustment
Screw

Pilot
Burner
Assembly

Pilot Tube

Thermopile
Leadwires

Local and
Remote Switch

REMOTE CONTROL

(MILLIVOLT)

POWER SUPPLY. PROVIDE

DISCONNECT MEANS AND
OVERLOAD PROTECTION AS
REQUIRED.

Figure 16 - Millivolt System Wiring Diagram