Figure 8 - Vertical Termination with Offset and Wall Strap

Wall Strap

Roof Flashing

45° Elbows

Ceiling Firestop

Roof Pitch

Minimum Height Above Roof

Flat - 7/12

1 ft. (30.48 cm)

7/12 - 8/12

1

1

/

2

ft. (45.72 cm)

8/12 - 9/12

2 ft (60.96 cm)

9/12 - 10/12

2

1

/

2

ft (76.20 cm)

10/12 - 11/12

4 ft (121.92 cm)

11/12 - 14/12

5 ft (152.40 cm)

14/12 - 16/12

6 ft (182.88 cm)

16/12 - 18/12

7 ft (213.36 cm)

18/12 - 20/12

7

1

/

2

ft (228.60 cm)

20/12 - 21/12

8 ft (243.84 cm)

INSTALLATION

Continued

ELECTRICAL HOOKUP AND REMOTE
RECEIVER DIAGRAM

An outlet box with two receptacles (see Figure 9) has been supplied
for your convenience and is located inside on the lower right side of
the fireplace.

The remote control receiver is factory wired and connected to the
convertible gas valve as shown in Figure 10.

Figure 9 - Duplex Outlet

Three-prong Plug

GAS SUPPLY TESTING

NOTICE: This section is intended as a guide for
qualified technicians installing gas to the appliance.

WARNING: Do not connect appliance before pres-

sure testing gas piping. Damage to gas valve may
result and an unsafe condition may be created.

The appliance and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 psig (3.5 kPa).

The appliance must be isolated from the gas supply piping system
by closing its individual shutoff valve during any pressure testing of
the gas supply piping system at test pressures equal to or less than
1/2 psig (3.5 kPa).

The gas control valve is secured underneath the firebox. Two 1/8"
ports are provided on the gas control valve for pressure test gauge
connections (see Figure 11).

Figure 10 - Remote Control Receiver

Figure 11 - Gas Control Valve

OFF

P

IL

O

T

ON

L

O

H

I

PI

LOT

E

A

16AI

7

TPTH

TP

TH

ON/OFF
Knob

Pilot Adjustment

Inlet
Pressure

Outlet Pressure

Flame Adjustment Knob

Pilot Gas
Line Do
Not Kink

To Pilot Burner

To Main
Burner

Outlet Box

OFF

TH

TP

TPTH

REMOTE OFF ON

ON

T

P

IL

O

OT

L

I

P

TPTH

TP

TH

Remote Control
Receiver

Convertible
Gas Valve

If an offset is necessary in the attic to avoid obstruction, it
is important to support the vent pipe every 3 ft. to avoid
excessive stress on the elbows and possible separation (see
Figure 8, page 7).
Clearances must be maintained between the roof and the ter-
mination. Refer to chart below.

INSTALLATION

Venting Installation (Con.)

Electrical Gookup and Remote Reeiver Diagram

Gas Supply Testing