MKIV Underdeck Unit 0
1. Swage stud at end of wire.
2. Open end of wire and install Norseman or Sta-Lok
®
stud after
foil is assembled.
3. Rod adapter nosepiece for Harken rod adapter stud: Threaded
nosepiece must have a positive lock as well as adhesive.
Use Harken stud with cotter pins. See page 22.
Options for Snaking Stay into Foils
Turnbuckle inside torque tube
Set up a pendant below making sure
to have a turnbuckle toggle.
Use a swage to swage turnbuckle
located just above the lower unit.
Check turnbuckle fit inside torque
tube. Requires a “third hand” to adjust.
Turnbuckle above swage
On smaller size wires 3/16" (4 mm)
a small turnbuckle should fit. Check
dimensions above for clearance.
Preassembly
Turnbuckle Options
WARNING! Using a threaded nosepiece with only
adhesive at the upper rod eye terminal may result
in headstay system failure. Make sure there is a
mechanical lock.