598-1007-02

Test and Adjustment

NOTES: When first turned on or when switching

from Manual to Auto mode wait 1

1

/

2

minutes for the unit to calibrate.

Testing with Range Boost on during day-
light may result in abnormal operation.

❒

Turn on the circuit breaker and light switch.

❒

Open the control access cover (on bottom of unit)
by pulling down on the tab of the rubber cover.

❒

Turn the sensitivity control to the center of its
adjustment, RANGE BOOST to OFF and the
ON-TIME to TEST position.

Sensor Bottom

Don't aim the control at:

•

Objects that change temperature rapidly, such
as heating vents and air conditioners, to help
avoid false triggering.

•

Where pets or traffic may trigger the control.

•

Nearby large, light-colored objects reflect-
ing light may trigger the shut-off feature. Do
not point other lights at the sensor.

MIN.

MAX.

SENSITIVITY

Range Boost

OFF

ON

ON TIME

TEST 1 5 20