FIREPLACE

INSTALLATION

Continued

FRAMING

Construct framing using dimensions shown if Figures

6, 7 and 8. (Use the figure applicable to your applica-

tion.) Figure 6 shows the framing dimensions prior

to having the appliance in place. If installing on a

platform, platform must be solid, flat and fully sup-

ported (see Figure 7). Once the unit has been fitted,

bring studs in against nailing flanges located on the

side of the appliance making sure a 1" clearance is

maintained as shown in Figure 8.
If the fireplace is to be installed directly on carpeting,

tile (other than ceramic) or any combustible mate-

rial other than wood flooring the fireplace must be

installed upon a metal or wood panel extending the

full width and depth of the fireplace.

Figure 6 - Framing Dimensions Prior to

Placing Appliance

Figure 8 - Securing Appliance with

Nailing Flanges

52

3

/

4

"

Min.

40

3

/

8

"

22

3

/

4

"

VENT PIPE INSTALLATION

A 6", B-1 type gas vent pipe is a double-wall, vent-

ing system (not supplied) which must be installed

during rough framing of the appliance. Any B-1

type gas vent system may be used for proper vent-

ing as long as the vent system is installed per the

vent manufacturerʼs recommendations.
DESA supplies this appliance with a tapered starter

pipe for a snug fit. Slide B-1 type vent pipe over

this starter pipe until vent pipe is fully seated.

Secure this first section of B-vent pipe by strap-

ping the connector around the vent pipe and then

tightening the strap with any 1/8" nut and bolt (see

Figure 9). Note: Visually inspect for proper vent

connection by looking inside top of appliance. If

connection does not appear to be correct, contact

your local service technician.

Figure 9 - Installing B-Vent Pipe

Nailing Flanges

1" Min. to Combustibles

Prepared Framing

Nails or Screws

B-1 Type
Vent (Not
Supplied)

Strap
(Fasten with
#6 Screw or
Bolt)

52

3

/

4

"

Min.

22

3

/

4

"

*

Figure 7 - Framing Dimensions Prior to

Placing Appliance Using a Platform

*As required by design as

long as ceiling clearance is

maintained

Advertising