Operating heater, Checking gas connections, Continued – Desa RP30D User Manual

Page 10

Advertising
background image

10

103569

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME CGP20, CGP20L AND RP30D

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation in the first column. If you
don’t smell gas, go to the next step.

5.

Press in control knob and turn coun-
terclockwise

to the PILOT

position. Keep control knob pressed
in for five (5) seconds (see Figure 16).

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the front of burner. The burner
and pilot are located behind the heat
shield. If needed, keep pressing igni-
tor button until pilot lights.

Note:

If pilot does not stay lit, refer

to Troubleshooting, pages 12 through
14. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot
with match. To light pilot with match,
see Manual Lighting Procedure
,
page 11.

Figure 17 - Pilot

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note

: If pilot goes out, repeat steps

3 through 7.

OPERATING
HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions ex-
actly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch;

do not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information
above.

2.

Make sure manual shutoff valve is
fully open.

3.

Turn control knob clockwise

Clockwise

to the OFF position.

Figure 16 - Control Knob In The OFF
Position

WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

Continued

CHECKING GAS
CONNECTIONS

Continued

Figure 15 - Checking Gas Joints

Propane/LP
Supply Tank

Control Valve Location

Manual
Shutoff
Valve

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

OFF

HIGH

PILOT

LOW

IGNITOR

Ignitor Button

Control Knob

Pilot

GRH/OV 007G

Thermocouple

Pilot Burner

Ignitor Electrode

Advertising