Owner’s manual, Connecting to gas supply, Checking gas connections – Desa RP30D User Manual

Page 9: Continued

Advertising
background image

9

103569

OWNER’S MANUAL

Figure 13 - Gas Connection

* An A.G.A. design certified manual shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional A.G.A. design certified
manual shutoff valve from your dealer. See
Accessories, page 17.

IMPORTANT:

Hold pressure regulator

with wrench when connecting it to gas pip-
ing and/or fittings.

CONNECTING TO
GAS SUPPLY

Continued

Tee Joint

Reducer
Bushing to 1/8"
NPT

1/8" NPT Plug
Tap

Test
Gauge
Connection *

Tee Joint

Pipe Nipple

Cap

Heater
Cabinet

Pressure
Regulator

3/8" NPT
Pipe
Nipple

Ground Joint
Union

Manual
Shutoff
Valve *

Typical Inlet
Pipe From
External Regulator
(11" W.C. to 14"
W.C. Pressure)

3" Minimum

Sediment
Trap

CHECKING GAS
CONNECTIONS

WARNING: Test all gas pip-

ing and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.

WARNING: Never use an open

flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. Bubbles forming
show a leak. Correct all leaks at
once.

CAUTION: Make sure exter-

nal regulator has been installed
between propane/LP supply and
heater. See guidelines under

Con-

necting to Gas Supply.

PRESSURE TESTING GAS
SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2
PSIG

1.

Disconnect heater and its individual
manual shutoff valve from gas supply
piping system. Pressures in excess of
1/2 PSIG will damage heater regulator.

2.

Cap off open end of gas pipe where
manual shutoff valve was connected.

3.

Pressurize supply piping system by ei-
ther using compressed air or

opening propane/LP supply tank valve.

4.

Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

Test Pressures Equal To or
Less Than 1/2 PSIG

1.

Close manual shutoff valve (see Fig-
ure 14).

Figure 14 - Manual Shutoff Valve

2.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

ON

POSITION

OFF

POSITION

Manual
Shutoff
Valve

Closed

Open

Note: Burner bracket
not shown for clarity

3.

Check all joints from propane/LP sup-
ply tank to manual shutoff valve (see
Figure 15, page 10). Apply mixture of
liquid soap and water to gas joints.
Bubbles forming show a leak.

4.

Correct all leaks at once.

PRESSURE TESTING
HEATER GAS
CONNECTIONS

1.

Open manual shutoff valve (see Fig-
ure 14).

2.

Open propane/LP supply tank valve.

3.

Make sure control knob of heater is in
the OFF position.

4.

Check all joints from manual shutoff
valve to control valve (see Figure 15,
page 10). Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

6.

Light heater (see Operating Heater,
pages 10 and 11). Check the rest of the
internal joints for leaks.

7.

Turn off heater (see To Turn Off Gas to
Appliance
, page 11).

8.

Replace front panel.

Continued