Powermax, max100, max200, hd3070, ht2000, Control pcb calibration – Hypertherm THC Control Board Replacement User Manual

Page 11

Advertising
background image

Page 8

128407 Kit Instructions

3

Remove access covers from the THC control
module and the THC plasma interface assembly.

4.

Install the replacement PC board in to the THC control module and attach electrical connections.

5

Attach the volt meter to measure the arc voltage between J5-2 and J5-3 in the plasma interface
assembly.

THC.91

GND

ELECTR

ODE

WORK

J5

12

345

IM360.01

POWERMAX, MAX100, MAX200,
HD3070, HT2000, HT2000LHF, AND
HT4001 PROCEDURE

1.

Turn off the power to the power supply.

2.

Turn off power to THC system
and remove power cord.

IM379.01

1

2

Powermax, MAX100, MAX200, HD3070, HT2000,

HT2000LHF, and HT4001 THC

Control PCB Calibration

Set volt meter to

measure 100-500 VDC.

Advertising