Page 7

128503 Kit Instructions

command THC

Plasma Interface Upgrade

10 Attach the volt meter to measure the arc voltage between J5-2 and J5-3 in the plasma interface

assembly.

THC.91

GND

ELECTR

ODE

WORK

J5

12

345

11 Replace the power cord to the THC control module.

IM380.03

12 Turn on the power to the THC.

13 Turn on the power to the power supply.