Monthly, Clean inside the power supply, Examine the coolant system – Hypertherm HPR130 Auto Gas Preventive Maintenance Program User Manual

Page 15

Advertising
background image

HPR130 Auto Gas Instruction Manual 808580

15

Preventive Maintenance Program

Monthly

Clean inside the power supply

1. Turn OFF the power to the power supply.

2. Remove the top and side panels of the power supply.

3. Use low pressure air or a vacuum to remove any accumulation of dust and particles from:

The top and side panels

The inside of the power supply

The fans

4. Remove dust and particles from circuit boards.

Be careful not to damage the circuit boards.

5. Install the top and side panels before you turn ON the power.

Examine the coolant system

Examine the coolant system for coolant leaks at all connections. Make sure you examine:

The ignition console

The torch main body

The internal connection in the power supply

WARNING!

ELECTRIC SHOCK CAN KILL

Disconnect electric power before performing any maintenance.

All work requiring removal of the power supply cover must be performed by
a qualified technician.

Read the Safety and Compliance Manual (80669C) for important safety
information.