WIRING DIAGRAMS

3

WARNING

SHOCK HAZARD: Always turn off the power and
unplug the cord or set the line disconnect switch to
Off before servicing the unit or changing consumable
parts. In the U.S., use a “lock-out / tag-out” procedure
until the service or maintenance work is complete. In
other countries, follow appropriate national or local
safety procedures.

Voltage Readings

a) Tolerance ± 10 % unless specified
b) Reference - to circuit common, lead 43 unless noted

V1

120 VAC

V7

24 VAC

V2

120 VAC

V8

14 VDC

V3

227 VAC

V9

320 VDC (OCV on 070784)

V4, V5, V6

20 VAC

V9

335 VDC (OCV on 070786)

Figure 5-3 Powermax190c 120/230 VAC Wiring Diagram

Power Supplies 070784 and 070786

Refer to Powermax190c Troubleshooting Guide in Section 3.