Stand alone THC test

Enables testing of Command THC as a stand alone unit.

Items needed: See parts list for details

#22 RS-422 Gas Console Dongle
#24 THC Dongle
#29 Extension Cable (2)
#29a Optical Isolator

Set-Up

1 – Connect the Optical Isolator to the communication port on the laptop computer.
2 – Connect Extension Cable to the Optical Isolator.
3 – Connect the other end of the extension cable to the RS-232 port on the RS-422 converter.
4 – Connect one end of the second extension cable to the RS-422 port on the RS-422 converter.
5 – Connect the other end of the second extension Cable to the THC Dongle.
6 – Connect THC Dongle to J4 on the THC Control board you want to test.