EQUIPMENT SHUTOFF VALVE - GA5010

For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2"
NPT pipe.

ACCESSORIES

Purchase these fireplace accessories from your local dealer. If they
can not supply these accessories, call DESA International’s Sales
Department at 1-866-672-6040 for information. You can also write
to the address listed on the back page of this manual.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• fireplace will not produce specified heat

You may feel your gas pressure is too low. If so, contact your local
natural gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA International’s Technical
Service Department at 1-866-672-6040. When calling please have
your model and serial numbers of your heater ready.

You can also visit DESA International’s technical services web site
at

www.desatech.com.

REPLACEMENT PARTS

Note:

Use only original replacement parts. This will protect your

warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply
original replacement part(s), call DESA International’s Technical
Service Department at 1-866-672-6040.

When calling DESA International, have ready
• your name
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original
replacement part(s), call DESA International at 1-866-672-6040 for
referral information.

When calling DESA International, have ready
• model number of your fireplace
• the replacement part number

SPECIFICATIONS

Btu (Low/High)

20,000/28,000

Type Gas

Natural Gas Only

Ignition

Piezo

Manifold Pressure

3.4" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

Minimum

5"

Shipping Weight

100 lbs. T-stat Model
97 lbs. Manual Model

WIRING DIAGRAM

Red

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black

Blue

CAUTION: Label all wires prior to disconnection

when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.

Figure 37 - Blower Wiring Diagram for Thermostat-Controlled
Models

TECHNICAL SERVICEWIRING DIAGRAM