45

3.5 Command Execution I/O Signals

Dedicated to Standard Mode

In standard mode the I/O commands can be executed using command execution I/O
signals. I/O commands execute the following.

⋅

Operate (start and stop) a program for each task.

⋅

Refer to or change variables from the external device.

⋅

Refer to or change inputs and outputs from the external device.

3.5.1 General Information about Commands

The table below shows the I/O commands functions.

I/O Command Functions

Command

Description of function

Program operation

⋅

Starts the program cycle (specified program).

⋅

Step-stops the program (specified program/all programs).

⋅

Immediately stops the program (specified program/all

programs).

⋅

Resets the program (specified program/all programs).

Speed setting

⋅

Sets the external speed.

⋅

Sets the external acceleration.

⋅

Sets the external deceleration.

Error number read

⋅

Outputs the error number to the system I/O area.

Type I variable write

⋅

Reads a value from the system I/O area and substitutes it for a

Type I variable.

Type I variable read

⋅

Outputs a Type I variable to the system I/O area.

Mode switching

⋅

Switches the robot operation mode.

Clear robot failure

⋅

Clears a robot failure from the external device.

Internal I/O write

⋅

Sets the state of internal inputs and outputs.

Internal I/O read

⋅

Outputs the state of internal inputs and outputs to the system I/O

area.