Remote Selection Button (13)

Remote control unit is connected to the device by pressing button 13. The wire feed speed

and welding voltage setting operations are performed via remote control. In this case,

potentiometers 11 and 12 of the panel are disconnected.

2.4 Panel SF 51 and SF 54 Setup parameters

Normal MIG welding Setup -parametres

Name of

parameter

Name on

display

Parameter

values

Factory

setting

Description

Pre Gas Time

PrG

0.0 – 9.9 s

0,0 s

Pre gas time in seconds

Post Gas Time

PoG

0.0 – 9.9 s

Aut

Post gas time in seconds or automatically according to
welding current (Aut)

Creep Start Level

CrE

10 – 170%

50 %

Percentage of wire feed speed:
10 % slowed start
100 % = no creep start function
170 % accelerated start

Start Power

StA

-9 ... +9

0

Strength of start pulse

Post Current Time

PoC

-9 ... +9

0

Post current

Arc Voltage

Ard

OFF, on

OFF

on: Display shows arc voltage
OFF: Display shows pole voltage

Cable Length

CAb

std, 5 – 80m std

Cable loss is calculated for optimal arc control and for the
Arc Voltage display

Common Setup -parameters for MIG processes

Name of

parameter

Name on

display

Parameter

values

Factory

setting

Description

Device Address

Add

3 or 6

3

Wire feeder bus address

Using features of

PMT Gun

Gun

OFF, on

on

on = PMT gun
OFF = other gun

Gas Guard

Connected

GG

no, YES

on

Implementation of gas guard

LongSystem Mode

LSY

OFF, on

OFF

on: Gives optimum welding characteristics with long
welding cables

Code Entry

Cod

---, Ent

---

Entering license codes manually:
1. Adjust right potentiometer to (‘Ent’).
2. Press REMOTE.
3. Set code with right potentiometer.
4. Choose next with left potentiometer.
5. Go back to point 3, until all codes have been set.
6. Approve by pressing REMOTE. (‘Suc cEs’)

Water Cooler

Coo

OFF, on

on

Enables water cooler

Wire Inch Stop

Inc

OFF, on

on

OFF = Stops wire inch in case arc does not ignite
on = Feeds wire as long as the welding gun start switch
is pressed.

FastMig SF 51, SF 54

8

Advertising
This manual is related to the following products: