EN

Auto Wire Inch

AIn

OFF, on

on

SuperSnake Automatic Wire Inch function. Wire Inch
button runs the filler wire from the wire feeder up to the
SuperSnake.

Demo Licence Time

dEt

3-h, 2-h, **’,
**’’, OFF

The remaining time for the WiseDemo licence
(readable value only).
3-h = max. 3 hours left
2-h = max. 2 hours left
**’ = ** minutes left
**’’ = ** seconds left
OFF = Demo period has expired.

Restore Factory

Settings

FAC

OFF, PAn,
ALL

OFF

Control panel reset function.
OFF = No reset
PAn = Settings will be restored, but memory channels
remain unchanged
ALL = All settings will be restored to factory values.

Setup-parameters for MMA welding

Name of parameter

Name on

display

Parameter

values

Factory

setting

Description

Start Power

StA

-9 ... +9

0

Strength of start pulse

Device Address

Add

3 or 6

3

Wire feeder bus address

Code Entry

Cod

---, Ent

---

Entering license codes manually:
1. Adjust right potentiometer to (‘Ent’).
2. Press REMOTE.
3. Set code with right potentiometer.
4. Choose next with left potentiometer.
5. Go back to point 3, until all codes have
been set.
6. Approve by pressing REMOTE. (‘Suc cEs’)

Restore Factory

Settings

FAC

OFF, PAn, ALL

OFF

Control panel reset function.
OFF = No reset
PAn = Settings will be restored, but
memory channels remain unchanged
ALL = All settings will be restored to
factory values

NOTE!

Arc Voltage Display function needs activation.

9