Use of gas test, Testing wire feed, Setup – Kemppi Pulse 2800 MVU User Manual

Page 11

Advertising
background image

Kempact™ pulse 800 mVu automotiVe / 0709 – 11

© Kemppi oy

Crater filling

Hot Start

Wire range/power/

Welding current

The Hot Start:

The Hot Start function is supposed to decrease faults in the start welding heat conductive materials

as for example aluminium. The Hot Start function is used with 1-MIG and pulse MIG welding. Time

is determined by SETUP parameters. The level of Hot Start can be changed by SETUP function.
The Hot Start level, Hot Start time, crater fill level and downslope time can be easily adjusted

using the ‘QUICK SETUP’ function:

1. First, press the SETUP button and then , while still pressing the SETUP button, press the

extra function button.

2. Adjust the Hot Start level.
3. Repeat step 1, upon which the display will show the next adjustable parameter.

Exit by pressing any button (except SETUP)

3.3.8. Use of gas test

If you press the gas test button, gas will begin to flow without any starting power source

or wire feed. Gas flow can be measured by using an external measuring device.
Cut off the gas flow by pressing the same button again, or the gun trigger. If the trigger

is not pressed again, the gas flow will end within 20 seconds.
The display will show “GAS” and the time.

3.3.9. Testing wire feed

The wire feed switch will start the wire feed motor without opening the gas valve. The

power source will start up, but without providing welding power. The wire feed range

will be 5m/min but can be adjusted as desired.

3.3.10. SETUP

Using the SETUP function, the user can change welding parameters which do not have their own

panel functions. These parameters can be set separately for 1-MIG and Pulse MIG. SETUP settings

are separate for each memory channel.