Kemppi Mastercool 12 User Manual

Page 16

Advertising
background image

16 – Master(tig) 2500, 2503, 3500, 3503 MLS

/ 0311

©

COPYRIGHT

KEMPPI

OY

Master(tig) 2500, 2503, 3500, 3503 MLS

/ 0311 – 17

©

COPYRIGHT

KEMPPI

OY

3.2.3.

Saving welding settings (MTM)

MTM panel has 10 memory channels for user settings. The selections are made in the MEMORY

field. Not only welding parameters but also function selections can be saved in the memory. MMA

welding values can also be stored in memory channels. Proceed as follows:

1. Press MEMORY button twice and if the SET light starts blinking the channel is free. If

the channel is reserved the led will remain lit.

2. Select memory channel by pressing CH button.
3. Select the parameters and press SAVE button.
4. Press MEMORY button twice. ON led is lit.
5. Start welding and adjust settings if necessary.

If the saved settings need to be adjusted the led has to be moved from ON to SET position in order

to select parameters. Press the SAVE button. It is also possible to save the currently used parame-

ters by pressing SET when the memory function is in OFF state (no lights on). Channel is cleared if

MEMORY and CH buttons are pressed simultaneously in SET mode.

3.2.4.

Adopting the saved settings

1. Select MEMORY by pressing the button.
2. Select memory channel by pressing the CH button.
3. Start welding.

3.2.5. Remote control memory channels

Memory channels are selected by pressing simultaneously both REMOTE and CH button. With the

remote control you can retrieve saved settings on memory channels.

3.2.6.

SETUP functions

A so called SETUP state is included for modifying panel functions. You can enter the SETUP state

by pressing the REMOTE (SETUP) button longer than normally. Exit is performed in the same

way. You can select the function (see list below) by pressing the arrow buttons and then change the

setting by turning the potentiometer.

Display

Function

Factory setting

A1 Upslope with constant time setting / gradient (steepness) setting

0 constant time

A2 Downslope with constant time setting / gradient (steepness) setting 0 constant time
A3 TIG antifreeze off / on

1 off

A4 MMA antifreeze off / on

1 on

A5 MMA hot start pulse non adaptive / adaptive

0 non adaptive

A6 Downslope cut off on / off

0 on

A7 MMA open circuit voltage 80V / 40V

0 80V

A8 2T downslope normal / cuts off by short switch action

0 normal

A9 Tacking automatics off / on

0 off

A10 Current at arc start steep / slightly sloped

0 steep

A11 Downslope linear / non-linear

0 linear

A12 MMA/TIG method selection with remote control off /on

0 off

A13 Search arc off / on

1 on

A14 Possibility to current freezing during downslope off / on

0 off

A15 Control of channels with torch up-down switch off / on

0 off

Advertising