Installation, Connection to the mains supply, Transport and lifting of the equipment – Kemppi Kempomig 4000R User Manual

Page 4: Siting the machine

Advertising
background image

4 KEMPOMIG 4000R, 4000WR - 0409

© COPYRIGHT KEMPPI OY

KEMPOMIG 4000R, 4000WR - 0409 5

© COPYRIGHT KEMPPI OY

EN 60974-1

60°

max

15°

rain water

– Preferably site the machine above floor level.

– See to that in front of the machine as well as at the rear of the machine there is at least 20 cm

free space to allow good circulation of the cooling air through the machine.

– Protect the machine against heavy rain and in hot circumstances against direct sunshine. Ensure

free circulation of the cooling air.

Degree of protection IP23 of the machine allows a water jet coming in 60 ° angle at its maximum

to hit machine´s outer covering.

Do not direct particle spray of grinding tools towards the machine.

2.3. CONNECTION TO THE MAINS SUPPLY

As standard, Kempomig power sources are delivered with 5 m mains cable without plug. If the

mains cable does not meet local electric regulations, you must change the cable to meet them.

Connection and change of the mains cable and plug must be carried out only by a

competent electrician.

During mounting of mains cable, remove the right side plate of the machine, seen from the

front.
When mounting the mains cable ensure the following: The cable is entered into the machine

through the inlet ring on the rear wall of the machine and locked with a cable clamp. The phase

conductors of the cable are coupled to connectors L1, L2 and L3.

Sizes of mains cables and fuse ratings for the machine at 100 % ED duty cycle are specified in the

table Technical data. In cables of S type there is protective grounding conductor coloured green-

yellow.

2.

INSTALLATION

2.1. TRANSPORT AND LIFTING OF THE EQUIPMENT

On the power source´s front panel and above the wire feeder unit there are handles for moving the

units on the floor.

Make sure that the unit is kept between lifting linens during lifting. When necessary,

use additional binding round the lifting linens and the unit´s upper part. Use protection

between the lifting device and the unit in order to eliminate impacts and shocks.

2.2. SITING THE MACHINE

Site the machine on a stationary, horizontal, dry and clean base from which there does not come

any dust etc. into inlet air through the rear grate.

Advertising