Operation and use controls, Welding and return current cables – Kemppi Kempomig 4000R User Manual

Page 5

Advertising
background image

4 KEMPOMIG 4000R, 4000WR - 0409

© COPYRIGHT KEMPPI OY

KEMPOMIG 4000R, 4000WR - 0409 5

© COPYRIGHT KEMPPI OY

2.4. WELDING AND RETURN CURRENT CABLES

Use only copper cables with cross-sectional area of at least 50 mm

2

.

Table below shows typical loading capacities of rubber insulated copper cables, when ambient

temperature is 25°C and conductor temperature is 85°C.

Cable

Duty cycle ED

Voltage loss / 10 m

100 %

60 %

30 %

50 mm

2

285 A

370 A

520 A

0,35 V / 100 A

70 mm

2

355 A

460 A

650 A

0,25 V / 100 A

95 mm

2

430 A

560 A

790 A

0,18 V / 100 A

To avoid voltage losses and heating, do not overload welding cables over permissible

values.

Fasten the earth clamp of the return current cable carefully, preferably directly onto the work piece.

The contact surface area of the clamp should always be as large and steady as possible. Clean the

contact surface from paint and rust.

3.

OPERATION AND USE CONTROLS

Kempomig 4000R

Signal lamp for main

switch

Signal lamp for

thermal protection

release

Main switch

Welding current connector (+)

Return current connector (–)

Adjustment for

MMA welding

dynamics *)

Mounting place

for V/A meter unit

MSD1

Control connector

for wire feeder unit

Fuse for control

connector (6,3 A)

Accessory drawer

Accessory drawer