ELECTRICAL CONNECTION

The installation of this appliance and the connection to the electrical network should be entrusted only to an

electrician perfectly to the fact of the normative regulations and which respects them scrupulously.

Protection against the parts under tension must be ensured after the building-in.

The data of connection necessary are on the stickers place on the hob casing near the connection box.

The connection to the main must be made using an earthed plug or via an omnipolar circuit breaking device

with a contact opening of at least 3 mm.

The electrical circuit must be separated from the network by adapted devices, for example: circuit breakers,

fuses or contactors.

If the appliance is not fitted with an accessible plug, disconnecting means must be incorporated in the fixed

installation, in accordance with the installation regulations.

The inlet hose must be positioned so that it does not touch any of the hot parts of the hob or oven.


Caution!

This appliance must only be connected to a network 230 V~ 50 Hz.
Always connect the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover, use a medium
screwdriver. Place it in the slits and open the cover.

* calculated with the simultaneous factor following the standard EN 60 335-2-6


Connection of the hob

The ceramic hob can be connected in different ways:

Monophase 230V~1P+N

Biphase 400V~2P+N


Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal

Monophase 230V~1P+N
Put the bridge between terminal 1 and 2.
Attach the earth to the terminal “earth”, the neutral N to terminal 4, the Phase L to one of the terminals 1 or 2.

Biphase 400V~2P+N
Attach the earth to the terminal “earth”, the neutral N to terminal 4, the Phase L1 to the terminals 1 and the Phase L2
to the terminal 2.

Caution! Ensure that you:
- Correctly attach the wires and the bridges.
- Tighten the screws properly.

Frequent loosening and screwing of the screws on the connection box risks damaging the efficiency of the
tightness once screwed. It is therefore advisable to keep screwing and unscrewing to a minimum.
Ensure that the cables are correctly inserted and tightly screwed down.

We cannot be held responsible for any incident resulting from incorrect connection or which could arise
from the use of an appliance which has not been earthed or has been equipped with a faulty earth
connection

Mains

Connection

Cable diameter

Cable

Protection calibre

230V~1P+N 50Hz

1 Phase + N

3 x 2.5 mm²

H 05 VV - F

H 05 RR - F

25 A *

400V~2P+N 50Hz

2 Phases + N

4 x 1.5 mm²

H 05 VV - F

H 05 RR - F

16 A *