3 factory service, 4 troubleshooting chart – Standard Horizon HX-300 User Manual

Page 35

Advertising
background image

Page 35

HX300

8.3 FACTORY SERVICE

In the unlikely event that the radio fails to perform or needs servicing, please

contact the following:
For repairs In USA

Standard Horizon

Attention Marine Repair Department

6125 Phyllis Drive, Cypress, California 90630

Telephone (800) 366-4566

For repairs in Canada

Westcom Marine

488 East 62nd Avenue

Vancouver BC V5X2G1

Phone (604)327-6280

An “RA” Return Authorization number is not necessary to send a product in

for service. Include a brief note describing the problem along with your name,

return address, phone number, and proof of purchase.

8.4 TROUBLESHOOTING CHART

SYMPTOM

PROBABLE CASE

REMEDY

The

key does not start the

scan.

No channel memorized. Enter desired channels into the

transceiver’s Scan memory. Refer

to section 6.9.1 “PROGRAMMING

SCAN MEMORY”.

Squelch is not adjusted. Press the key several times

until the “

SQL” indicator blinks,

then press the

key until the

” icon disappears. Further

adjustment of the squelch level

may eliminate incoming signal.

Cannot select between USA,

INTL, Canadian bands.

Proper operation not fol-

lowed.

Hold down the key and press

the

key.

Speaker audio is not heard
when the key is press and

hold.

Low battery.

Charge battery. Refer to section

4.2.3 “BATTERY CHARGING”.

Audio volume is too low. Press the key several times

until the “

VOL” indicator blinks,

then press the

key several

times.

Some keys does not operate.

Key lock is on.

Hold down the

key for 2 sec-

onds to turn the Key Lock off.

” indicator on the LCD does

not appear while charging.

Detective battery

FNB-

122LI.

Contact your Standard Horizon

dealer.

Advertising