CAUTION: Empty communication ports must be closed off with foam blocks, TracJack

blanks or Extron Single and/or Double MAAP blanks to maintain Fire Classification.

Activate Cat 5e 2A

Jack (Supplied)

Activate Bezel

(Supplied)

Extron Device Bezel

(Supplied)

Extron Device Bezel - Supplied with AV3ATC & AV3CTC. (Extron
Devices Sold Separately Through Extron Distributors Only.)

Pass & Seymour ACTIVATE Bezel and Communication Jack
(Supplied with AV3ATC & AV3CTC units).

Ortronics TracJack Bezel & Communication Jack (Bezel Supplied
with AV3ARTTC and AV3CRTTC, TracJacks sold separately).

Ortronics Series II Bezel & Communication Jacks (Series II Bezel
Included with AV3ARTTC and AV3CRTTC, Series II Modular
Inserts Sold Separately).

Extron Blank

Devices Plate

(Not Supplied)

Extron Bezel

(Supplied)

TracJack Blank

(Supplied)

Ortronics TracJack

Bezel

Comm Jack
(Sold Separately)

Pass & Seymour
Keystone Bezel

Foam Block
(Supplied)

TracJack

(Sold Separately)

NOTE: This Bezel Accommodates (1) Single and (1) Double or

(3) Single MAAPs (Mini Architectural Adapter Plates)
Extron Devices.

Step 10

Wire and snap communication jacks in adapters as shown.

Step 11 Insert blanking plugs, plates or neoprene foam blocks in unused communication ports.

Units employing Activate or Ortronics Communication Modules:
In order to maintain UL Fire Classification, all communication modules and/or blank inserts (factory or customer supplied) must be UL
Listed Communication Circuit Accessories. Modules and /or blank inserts must have a secure fit in the supplied communication
brackets with no visual openings between communication modules and communication brackets. All unused openings must be
sealed with the appropriate blanking plugs. Seal any openings between pass-through type cables and the bezel using the
appropriate blank insert or foam plug (see step 11).

Units employing Extron Devices:
In order to maintain UL Fire Classification, all Extron devices must have a secure fit in the supplied device mounting bezel with
no visual openings between the devices and the mounting bezel. Total weight of all devices (excluding device mounting bezel)
must not exceed 4 ounces (113.4 grams). All unused openings must be sealed with the appropriate blank plate (see step 11).