Legrand RC3APTCBK User Manual

Page 3

Advertising
background image

3

Step 10. Wire and snap communication

Step 11. Insert blanking plugs or neoprene foam

jacks in adapters as shown.

block in unused communication ports.

NOTE: To maintain UL Fire Classification, all communication modules or blank inserts (factory or customer supplied) must be UL Listed

communication circuit accessories, and must fit securely in the supplied communication brackets with no visible openings between
the module and bracket. Supplied foam plugs must be used when passing cables through the communication openings.

Step 12. Snap communication jacks or

Step 13. Align gasket over receptacle and press

communication port plugs into flange.

bead into flange channel.

CAUTION: Gasket must be set in place to provide scrub water seal.

Point Keystone Tab
Away From Bezel.

TracJack Blank (Supplied)

CAUTION: Empty communication ports must be closed off

with foam plugs or TracJack blanks to maintain
fire classification.

Foam Plug (Supplied)

TracJack Sold Separately

Communication Jack
Sold Separately

Ortronics Series II Bezel
and Communication Jack
(Series II Bezel Included;
Series II Modular Inserts
Sold Separately)

Point Keystone Tab
Away From Bezel.

Lower Level Bezel Installation
(Typical for Fiber Installations)
Fiber Jack Sold Separately

Pass & Seymour Activate

Bezel and Communication
Jack (Supplied with
RC3ATC and RC3CTC Units)

Point Keystone Tab
Away From Bezel.