![background image](/files/794503/content/doc003.png)
3
4c. Top of Flange adjusted flush with Floor Covering.
4b. Confirm top edge of Flange is level with Floor Covering
with Level or Straight Edge.
4e. Seal edge of Flange with Grout or Silicone.
5. Re-attach Lid in Trim Ring and re-insert “L” Pins and
Hinge Clip Cap.
6. FINISHING (Carpet Installation – FPC Series): Cut
Carpet Insert (see Template on last page) and mount
to Lid with Carpet Tape or Glue.
Hold-Down
Screw
Beveled
Washer
Nylon
Shoulder
Washer
Adjusting
Screw
Trim Ring
Tile
Carpet
Insert
4d. RFB6 Installation Only – Top of Flange adjusted
flush with Floor Covering.
ATTACHMENT
SCREW
NON-FLANGED
STYLE FLOOR PORT
TRIM RING
ADJUSTING
SCREW
BEVELED
WASHER
NYLON
SHOULDER
WASHER
7. Installation complete.