Iv series presets, Furniture feed activations – fpff series, Pk series preset inserts – Legrand FP Series Activation Covers User Manual

Page 5: N-r-g-bloc, Series preset inserts, Floorport bracket compatibility

Advertising
background image

5

1. Insert lower lip of Grommet into the

communication opening of the Cell.
Push the top of the Grommet inward
until it snaps into the Cell opening.

2. Install Barrier Base to N-R-G Deck

as shown using #10-32 Screws.
Follow directions below to
complete installation.

3. Install Cell Closure Plate to N-R-G

Deck as shown using #10-32 Screws.

FURNITURE FEED BARRIER KIT – Cat. No. NRGKIT

For use with UL Listed KAM Industries LTD, dba Cordeck Cellular Metal Raceway Fittings, catalog number
NB or N-R-G Bloc

®

IV Series Presets

Communication Bend

Radius Grommet

N-R-G Bloc

Interior

Mount Barrier
Ear at bottom

#10-32 x 5/16" Self
Tap (Phillips Drive)

Cell Closure

Plate

1. Select suitable Upper Partition height for concrete

pour depth and position over Lower Partition. Attach
Trim Ring. Mount Upper Partition to Trim Ring with
#8-32 x 1/4 FHMS. Fasten Upper and Lower Partitions
with #8-32 x 3/8 PHMS.

2. Place Gasket on Flange and remove necessary

Screw Plugs for intended Conduit Fitting.

FURNITURE FEED ACTIVATIONS – FPFF SERIES

#8-32 x 1/4 FHMS

#8-32 x 1/4 PHMS

Trim Ring

1 1/4" x 2" Trade Size

NPT Reducer

1 1/4" Trade Size

NPT Screw Plug

1" Trade Size

NPT Screw Plug

Trim Ring

Gasket

Communication Plate

with 2" Trade Size NPT

opening (not listed for

power applications)

Upper Partition

Bracket

Lower Partition

Bracket

#8-32 x 7/8"

FHMS (6X)

Power Plate with

1" Trade Size
NPT Opening

COVER

ACTIVATION

BARRIER

COMMUNICATION

ASSEMBLY

ASSEMBLY

ASSEMBLY

BRACKET

FPBTC

FPCTC

(1) WPACR

(2) DTB-2

FPBT
FPCT

FPFFTC

(1) PKKIT

(1) DTB-2FP

FPFFT

These fittings are for indoor installation on carpet or tile
covered concrete floors that contain a cellular raceway
system that has a minimum of 2-1/2" [64 mm] of concrete
topping over the top of the deck. A typical UL Filer
Classified floor activation will consist of the following
components:

PK Series Preset Inserts

“( )” Maximum Quantity of Units Allowed Inside of Preset Insert

COVER

ACTIVATION

BARRIER

COMMUNICATION

ASSEMBLY

ASSEMBLY

ASSEMBLY

BRACKET

(1) NPACR

(2) DTB-N3

(2) DTB-N3 or
(1) NRGACT8 or

(1) NPACR-SGL

(1) NRGRT8 or

(1) NRGACT12 or
(1) NRGRT12

FPBTC

(1) NRGACT8 or

FPCTC

(1) NPACR-DD

(1) NRGRT8 or
(1) NRGACT12 or
(1) NRGRT12

FPBT

(1) NPACR-VDD

(1) NRGACT8 or

FPCT

(1) NRGRT8 or
(1) NRGACT12 or
(1) NRGRT12

(2) NPACR-VDD

FPFFTC

(1) NRGACT8 or

FPFFT

(1) NRGRT8 or

(1) NRGKIT

(1) NRGACT12 or
(1) NRGRT12

N-R-G-Bloc

®

Series Preset Inserts

“( )” Maximum Quantity of Units Allowed Inside of Preset Insert

FLOORPORT BRACKET COMPATIBILITY

Advertising