4.1.2. Setting Non-dim channels - VX Model Only

Non-dim channels switch from full off to full on without any intermediate dimming. This can be
useful for connecting devices that do not dim well, such as some types of motors or transformer
controlled fixtures.

There are two ways to set a channel on-dim channel:

1) Set a single channel by setting the DMX code shown below, and press ‘enter’.

DMX

Function

801

Channel 1 Non-dim

802

Channel 2 Non-dim

803

Channel 3 Non-dim

804

Channel 4 Non-dim

805

Channel 5 Non-dim

806

Channel 6 Non-dim

807

Channel 7 Non-dim

808

Channel 8 Non-dim

809

Channel 9 Non-dim

810

Channel 10 Non-dim

811

Channel 11 Non-dim

812

Channel 12 Non-dim

To reset all channels back to normal operation:
Set 899 on the thumbwheel and press ‘enter’ or ‘reset’.

2) Set several channels at once.

Connect a functioning console to the VX dimmer.

Set the DMX address to 800.

Channels with levels above 10% will be programmed as non-dim. The settings are memorized
when ‘enter is pressed.

To reset all channels back to normal operation:
Setting 899 and pressing ‘enter’ or ‘reset’ clears all non-dim channels.