4.1.2. Setting Non-dim channels - VX Model Only
Non-dim channels switch from full off to full on without any intermediate dimming. This can be
useful for connecting devices that do not dim well, such as some types of motors or transformer
controlled fixtures.
There are two ways to set a channel on-dim channel:
1) Set a single channel by setting the DMX code shown below, and press ‘enter’.
DMX
Function
801
Channel 1 Non-dim
802
Channel 2 Non-dim
803
Channel 3 Non-dim
804
Channel 4 Non-dim
805
Channel 5 Non-dim
806
Channel 6 Non-dim
807
Channel 7 Non-dim
808
Channel 8 Non-dim
809
Channel 9 Non-dim
810
Channel 10 Non-dim
811
Channel 11 Non-dim
812
Channel 12 Non-dim
To reset all channels back to normal operation:
Set 899 on the thumbwheel and press ‘enter’ or ‘reset’.
2) Set several channels at once.
•
Connect a functioning console to the VX dimmer.
•
Set the DMX address to 800.
•
Channels with levels above 10% will be programmed as non-dim. The settings are memorized
when ‘enter is pressed.
To reset all channels back to normal operation: