Installation and operating instructions, Mechanical installation, Electrical connection – Louroe Electronics LE-572 User Manual

Page 2

Advertising
background image

CONNECTING VERIFACT CGC MICROPHONE TO A LOUROE RECEIVING DEVICE (BASE
STATION OR AUDIO INTERFACE ADAPTER)

After microphone connection has been made, run 2 conductor shielded cable to the Louroe Base Station or interface
adapter.

If Louroe Base Station is AP Series, DG-12/25 series, IF-1, IF-4 or IF-8:

RED wire to terminal A of base station
BLACK wire to terminal B of base station
BARE wire to terminal C of base station

NOTE: In the interconnection diagram, black wire is used instead of bare to represent ground.

If DVR’s audio input is 3.5mm (1/8”port), a 3.5mm adapter must be connected to one end of the RCA cable.

Check DVR manufacturer’s instructions to determine if 3.5mm audio input is mono or stereo.

CONNECTING VERIFACT CGC MICROPHONE DIRECTLY TO A DVR OR IP CAMERA

If a Louroe Audio Base Station or interface adapter is not used and Verifact CGC is to be connected
directly to a DVR or soundcard, etc. use the following procedure (See last page for interconnection diagram)

1) Apply 12 Vdc (100 mA minimum) to PC board’s terminals A and C, A is positive, C is

ground

2) Run a single conductor shielded cable 22 gauge with a 24 gauge drain wire to DVR or

IP Camera

3) Solder on an RCA connector with wire from terminal B of microphone going to the tip

of the plug, and wire from terminal C of microphone going to the sleeve of RCA plug.

4) Connect RCA plug into “Audio In” jack of DVR or soundcard.

Microphone pre-amp is mounted in a protective plastic housing with openings for wire connection and microphone
sensitivity adjustment. If microphone is to be mounted in a special housing, a black grommet is included for optional use
in securing the microphone element to the inside of a camera housing or special housing. A 1/8” minimum opening must
be provided for microphone pickup. Microphone should be located within 4’ to 6’ of the subject. Avoid ceiling mounts
in excess of 10’ in height.

MECHANICAL INSTALLATION

Verifact CGC Microphone will connect directly to any Louroe Base Station (AP Series or DG Series) or to the IF-1, IF-4
or IF-8 Interface Adapters. A small terminal block is located on the microphone pre-amp, and marked A, B, C:

A represents

12 Vdc (positive)

B represents

Audio (Mic output)

C represents

Ground (negative)

ELECTRICAL CONNECTION

NOTE:

Verifact CGC Microphone is NOT recommended for
outdoor use or in areas with high moisture content.

Page 2 of 4

LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406

TEL (818) 994-6498

FAX

994-6458

website: www.louroe.com e-mail: [email protected]

(818)

®

INSTALLATION AND OPERATING INSTRUCTIONS

Cgc_mic_inst_12/14

®

®

®

®

®

Advertising