Owner’s manual, Operating heater, Continued – Desa FGH-30NGB User Manual

Page 13

Advertising
background image

13

105568

OWNER’S MANUAL

LIGHTING

INSTRUCTIONS

NON-THERMOSTAT MODELS
FA-20BB, FA-30BB AND
FGH-30NGB

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any

part has been under water. Imme-
diately call a qualified service tech-
nician to inspect the appliance and
to replace any part of the control
system and any gas control which
has been under water.

WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

FOR YOUR SAFETY

READ BEFORE

LIGHTING

1.

STOP! Read the safety information
column 1.

2.

Make sure the equipment shutoff
valve is fully open.

3.

Turn control knob clockwise
to the OFF position (see Figure 18).

4.

Wait five (5) minutes to clear out any gas.
Then smell for gas including near the
floor. If you smell gas, STOP! Follow “B”
in the safety information at left. If you
don’t smell gas, go to the next step.

5.

Turn control knob counterclockwise

to the PILOT/IGN position.

Press in control knob for five (5) sec-
onds (see Figure 18).

Note:

You may be running this heater

for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds. This will
allow air to bleed from the gas system.
• If control knob does not pop up when

released, contact a qualified service
person or gas supplier for repairs.

6.

Release control knob pressure and
turn clockwise

to OFF.

7.

Press in control knob and turn back
to PILOT/IGN. This should cause the
piezo ignitor to spark and light the
pilot gas. If needed, repeat steps 5
through 7 until pilot lights.

Note:

If pilot does not stay lit, refer

to Troubleshooting, pages 15 through
17. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot
with match. To light pilot with match,
see Manual Lighting Procedure
.

8.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

If pilot goes out, repeat steps

3 through 7.

9.

To light burner, slightly press in con-
trol knob and turn counterclockwise

. Release downward pressure

on control knob while turning. Set con-
trol knob to desired heating position.

Note:

Both HIGH, MED, and LOW

are locked positions. You must press
in control knob before turning it
from these positions.

OPERATING
HEATER

Continued

CAUTION: Do not try to ad-

just heating levels by using the
equipment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.

Slightly press in control knob and
turn clockwise

to the

PILOT/IGN position.

2.

Fully press in control knob and turn
clockwise

to the OFF position.

3.

Turn off all electric power to the ap-
pliance if service is to be performed.

Shutting Off Burner Only (pilot
stays lit)

Slightly press in control knob and turn
clockwise

to the PILOT position.

Figure 18 - Control Knob In The OFF
Position

Figure 19 - Pilot

Thermocouple

Ignitor Electrode

Pilot Burner

1.

Remove front panel (see Figure 7,
page 8).

2.

Follow steps 1 through 5 under Light-
ing Instructions
.

3.

With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.

4.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

5.

Replace front panel.

MANUAL LIGHTING

PROCEDURE

Advertising