Datalogic Scanning STARGATE User Manual

Page 19

Advertising
background image

CONNECTIONS

3

CAUTION

To configure the STARGATE™ base station use the cable and the
adapter listed in par. 3.1. F
or further details see par. 4.3.



The RS485 bus system and the eventual power are propagated from one base
station to another through a cable having the following minimum characteristics:
− 2 twisted pair AWG 24 wire
− Impedance: 120 Ω
− Propagation velocity: 66%
− Capacitance between two connectors: 49 pF/m
− Conductor resistance: 0.8 Ω/m
− Maximum length: 1200 m


Pinout

The custom cables to be used in the RS485 connection have two RJ45 connectors
(see Figure 5).

The cable connecting the first base station to the RS232/RS485 converter has the
following pinout:

6

7

RJ45

2

1

RJ45

CONVERTER

side

STARGATE™

side

Twisted Pair

RS485+

RS485-

3

5

VDC-

Figure 9 - Converter/STARGATE™ Custom Cable Pinout

11

Advertising