Datalogic Scanning STARGATE User Manual

Page 32

Advertising
background image

STAR H GATE™

4

4. Select

the

Base stations option from the Settings menu: the RF Base stations

dialog box appears;

5. Digit

2000 in the Edit box positioned in the right upper part of the dialog box and

click on the Add button. The address will then be displayed in the list on the left;

6. Select

the

2000 address number from the list and click on the Config button. A

window showing the STARGATE configuration parameters will appear;

7. Double-click on the Address parameter and the Setting value dialog box will be

displayed. Change the address value in the range 0-1999 and click on the OK
button to confirm and exit the dialog box;

8. In the dialog box listing the configuration parameters select the RS485 interface

value by double-clicking on the Interface parameter. Then, click on the OK
button to confirm and exit the dialog box;
DO NOT CHANGE CONFIGURATION PARAMETERS OTHER THAN
ADDRESS AND INTERFACE.

9. Send the new configuration to STARGATE™ by clicking on the

Update Cfg button. Then, click on the EXIT button to exit the dialog box;

10. Disconnect the first STARGATE™ and connect individually the other ones

to the PC serial port and power them;

11. For each STARGATE™ digit 2000 in the Edit box positioned in the right upper

part of the dialog box and click on the Add button. The address will then be
displayed in the list on the left;

12. For each STARGATE™ select the 2000 address number from the list and click

on the Config button. A window showing the STARGATE™ configuration
parameters will appear;

13. Double-click on the Address parameter and the Setting value dialog box will be

displayed. Change the address value in the range 0-1999 and click on the OK
button to confirm and exit the dialog box;

14. In the dialog box listing the configuration parameters select the RS485 interface

value by double-clicking on the Interface parameter. Then, click on the OK
button to confirm and exit the dialog box;
DO NOT CHANGE CONFIGURATION PARAMETERS OTHER THAN
ADDRESS AND INTERFACE.

15. Send the new configuration to the STARGATE™ individually connected by

clicking on the Update Cfg button. Then, click on the EXIT button to exit the
dialog box;

16. Once all the base stations have been configured, close the RF Base Stations

dialog box by clicking on the Exit button;

17. Set the communication parameters of the RS232/RS485 converter and

position the jumpers terminating the network (see par. 3.2 and par. 3.3);

18. Physically connect the STARGATE™ base stations in the RS485 network;