Lynx Studio L22 User Manual

Page 14

Advertising
background image

Page 14

Word256, Header/Word, or Header/Word256 the displayed sample rate must
match the rate of the incoming clock being used for synchronization. This
will ensure the correct sample rate is stored in the file’s WAV header, and that
audio will playback at the correct sample rate.

Digital Format – Allows selection of either AES/EBU or S/P DIF formats for Digital

In and Digital Out.

Digital Mode – Selects the mode for the Sample Rate Converter on the Digital Input.

SRC On – Default. The sample rate converter is on.

SRC Off: Clock Synchronous – Turns off the sample rate converter and indicates

that the digital input and digital output clocks are synchronous. This mode is
useful when the digital output is feeding the digital input either directly or
through an external device with no sample rate converter.

SRC Off – The sample rate converter is off. When in this mode the Sample Clock

Source must be set to Digital. Use this mode when recording non-audio formats
such as Dolby Digital, DTS or others formats that require bit-perfect transfers.

SRC On: Digital Out – The sample rate converter is turned on, but it is used by

the Digital Output instead of the Digital Input. The Digital Input sample rate
will determine the actual rate of the Digital Output. This mode is useful when
sending audio to external equipment at a different rate than it was recorded.

Transmit Only – Disables the Digital Input and the sample rate converter. Used

for testing purposes only.

Digital Input Status – Displays real-time status of the digital input, updated 4 times a

second.

Digital In Rate – Displays the measured rate of the incoming digital signal.

SRC Ratio – Indicates the sample rate conversion ratio in SRC On mode.

Digital In Mode – Displays real-time status of the digital input. Professional status

is generally associated with an AES/EBU signal, and consumer status is
generally associated with an S/P DIF signal.

Analog Trim – Sets the nominal analog input and output levels for the Lynx L22 to

either +4dBu or -10dBV. Two controls are provided, each for a pair of inputs and
outputs.

Frequency Counters – Displays the real-time clock frequency for the following sources:

L/R Clock – Left/Right Clock, which is the currently selected sample rate.

Digital Input – This is the same clock as the Digital In Rate above.

External – Clock signal from the SYNC IN connector on the L2Sync cable.

Header – Clock signal from the CLOCK IN header connector.

LStream 1 – Clock signal from the LStream port on the L2Sync connector.

LStream 2 – Clock signal from the LStream port on the board mounted header.

PCI Bus – The speed of the PCI Bus of the host computer.

Mixer Reference

Advertising