Installation – Desa CRN30 User Manual

Page 13

Advertising
background image

www.desatech.com

13

107883-01H

INSTALLATION

Continued

PRESSURE TESTING GAS SUPPLY
PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)
1. Disconnect appliance with its appliance main

gas valve (control valve) and equipment

shutoff valve from gas supply piping system.

Pressures in excess of 1/2 psig will damage

heater regulator.

2. Cap off open end of gas pipe where equipment

shutoff valve was connected.

3. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas or opening main gas valve

located on or near gas meter for natural gas

or using compressed air.

4. Check all joints of gas supply piping system.

Apply a noncorrosive leak detection fluid to

all joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff

valve to gas supply. Check reconnected fit-

tings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG
(3.5 kPa)
1. Close equipment shutoff valve (see Figure 16).
2. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas or opening main gas valve

located on or near gas meter for natural gas

or using compressed air.

3. Check all joints from gas meter for natural gas

(see Figure 17) or propane/LP supply tank for

propane/LP gas, to equipment shutoff valve

(see Figure 18). Apply a noncorrosive leak

detection fluid to all joints. Bubbles forming

show a leak.

4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 16).
2. For natural gas open main gas valve located

on or near gas meter. For propane/LP gas open

propane/LP supply tank valve.

3. Make sure control knob of heater is in the OFF

position.

4. Check all joints from equipment shutoff valve

to thermostat gas valve (see Figure 17 or 18).

Apply a noncorrosive leak detection fluid to

all joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 14).

Check all other internal joints for leaks.

7. Turn off heater (see To Turn Off Gas to Ap-

pliance, page 15 or 16 depending on your

model).

8. Replace front panel.

Figure 18 - Checking Gas Joints for

Propane/LP Gas

Figure 16 - Equipment Shutoff Valve

Equipment
Shutoff
Valve

Propane/LP
Supply Tank

Thermostat Gas Valve

Open

Closed

Equipment
Shutoff Valve

Figure 17 - Checking Gas Joints for

Natural Gas

Equipment
Shutoff
Valve

Gas
Meter

Thermostat Gas Valve

Advertising