Operating heater – Desa CRN30 User Manual

Page 16

Advertising
background image

www.desatech.com

107883-01H

16

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information, page

15, column 2.

2. Make sure equipment shutoff valve is fully

open.

3. Turn thermostat control knob clockwise

to the OFF position (see Figure 22).

4. Wait five minutes to clear out any gas. Then

smell for gas, including near the floor. If you

smell gas, STOP! Follow “B” in the safety

information, page 15, column 2. If you donʼt

smell gas, go to the next step.

5. Turn thermostat control knob counter-

clockwise

to the pilot position. Press

in thermostat control knob for 5 seconds

(see Figure 22).

Note:

You may be running this heater for

the first time after hooking up to gas supply.

If so, you may need to press in thermostat

control knob for 30 seconds or more. This

will allow air to bleed from the gas system.

• If thermostat control knob does not pop

up when released, contact a qualified ser-

vice person or gas supplier for repairs.

6. Keep thermostat control knob pressed in

while pushing down and releasing the ig-

nitor button (see Figure 22). This will light

pilot. If necessary, continue to press ignitor

button until pilot lights.

If pilot does not light

• turn thermostat control knob clockwise

to the OFF position

• repeat steps 5 and 6

If pilot does not stay lit after several tries

• refer to Troubleshooting, page 19

• contact a qualified service person or gas

supplier

Until repairs are made, light pilot with

match. To light pilot with match, see

Manual Lighting Procedure, page 17.

7. Keep thermostat control knob pressed in

for 30 seconds after lighting pilot. After 30

seconds, release control knob.

Note:

If pilot goes out, repeat steps 3

through 7. This heater has a safety interlock

system. Wait one minute before lighting

pilot again.

OPERATING HEATER

Continued

8. Turn thermostat control knob counter-

clockwise

to the desired heating level.

The main burner should light. Set control

knob to any heat level between 1 and 5 (see

Figure 24).

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Figure 22 - Control Knob In The OFF

Position (Piezo Ignitor Shown)

Figure 23 - Pilot

Figure 24 - Burner Patterns

Control
Knob

CRP16T
CRN18T

CRP26T
CRN30T

Ignitor Electrode

Pilot Burner

Thermocouple

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn thermostat control knob clockwise

to the OFF position.

2. Turn off all electric power to the appliance

if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn thermostat control knob clockwise

to the PILOT position.

OF

F

P

ILO

T

Control Knob

Ignitor Button

Advertising