McCall Series I Reach-In Manual

Location

Cabinets represented in this manual are intended for indoor use

only. Be sure the location chosen has a floor strong enough to

support the total weight of the cabinet, 1000 pounds (450 kg)

per door section. Reinforce the floor if necessary to provide for

maximum loading. For the most efficient operation, be sure to

provide good air circulation inside and out. The location should

be selected so that the power cord can be connected without

any extensions.

Inside Unit

Take care not to block airflow to the fans or heating elements

and allow space along the front, back and sides.

Outside Unit

Be sure that the unit has access to ample air; avoid hot corners and

locations near stoves and ovens. Provide a minimum clearance

of 12” (30cm) above the unit that is open to the front.

Door Removal

The doors can be removed during installation if necessary.

Remove the door by opening the door to 90˚, lift it up and ease

it out of the hinge brackets

Leg, Caster, Utility Base Installation

Some cabinets may weigh over 1000 pounds (450

kg). Use a lifting device capable of supporting the

unit when removing skid or installing legs, casters

or utility base.

To install the legs, or casters refer to Figure 1. To install the

utility base, refer to Figure 2. Proceed as follows:

Remove unit from skid.
Raise unit to access leg/caster mounting holes on bottom

of unit.
Attach the legs, casters or utility base to bottom of cabinet

using hex head bolts.

Leveling

After the cabinet has been placed in the desired location, cabinets

with legs must be leveled. Level units from front to back and

from side to side. Leveling will insure proper door operation

and removal of condensate. Cabinets with casters must have

the caster brake set so the cabinet cannot move.

Stabilizing

It is very important that all legs are properly adjusted to keep

the cabinet level, evenly distribute the weight and to make sure

the unit will not rock, lean or be unstable.

1.
2.

3.

Figure 1. Leg or Caster Installation

Figure 2. Utility Base Installation