O - recall configuration…… 63, O - recall configuration – Measurement Computing Digital488/80A User Manual
Page 69

O - Recall Configuration
SYNTAX
Oval
Load configuration
val
, where
val =
value from
0
to
100
.
O?
Returns currently loaded configuration
val
.
DESCRIPTION
The Recall Configuration (
O
) command is used to load a previously-saved configuration from Non-Volatile RAM and
use it as the present configuration. The argument of the command
val
may range from
0
to
100
. Configuration
0
is
the power-up configuration. Any load of a configuration not previously-saved with the Save Configuration (
S
)
command, configures the channel with the default setting for each command (i.e. Data Format
F0
, Bus Terminator
Y0
,
etc.) Issuing an
O?
query command returns the configuration number last recalled.
EXAMPLE
PRINT#1,"CLEAR08"
Line 1: Reset the Digital488/80A..
PRINT#1,"OUTPUT08;O5X"
Line 2: Load Configuration
5
from Non-Volatile RAM for use as
the present configuration.
Digital488/80A User’s Manual
967695
Digital488/80A Commands 63