6 SPECIFICATIONS

Typical for 25°C unless otherwise specified.

POWER CONSUMPTION

+5V

CIO-CTR10HD

475 mA typical, 590 mA max

CIO-CTR20HD

800 mA typical, 1A max

COUNTER SECTION

Counter type

9513

Configuration

CIO-CTR10HD

Two 9513 devices. 5 counters per 9513, 16 bits
each

CIO-CTR20HD

Four 9513 devices. 5 counters per 9513, 16 bits
each

Clock input frequency

7 Mhz max

X2 Clock input source

1 MHz (10 MHz Xtal divided by 10), 5 MHz (10

MHz Xtal divided by 2) or external; software
selectable

High pulse width (clock input) 70 ns min
Cycle time (clock input)

145 ns min

Gate pulse duration

145 ns min

Input low voltage

−

0.5V min, 0.8V max

Input high voltage

2.2V min, 5V max

Output low voltage

0.4V max @ 3.2 mA

Output high voltage

2.4V min @

−

200 µA

Crystal oscillator clock source 10 MHz
Frequency accuracy

CIO-CTR##HD

100 ppm

CIO-CTR##HD/H50

50 ppm

DIGITAL I/O

Interrupts

2 to 7, software selectable

Interrupt enable

Programmable

Interrupt sources

External

ENVIRONMENTAL

Operating temperature range

0 to 50°C

Storage temperature range

−

20 to 70°C

Humidity

0 to 90% non-condensing