Configuration of the board

Configuration of the IRIG format to be used as well as the serial ports can be done by an
on board DIP-Switch.

Selecting the IRIG format

The IRIG or AFNOR format to be used can be selected by switches SW1-7 to SW1-10.
Please note that modulated and unmodulated code formats are applied to the board at
separate inputs.

Code

SW1-7

SW1-8

SW1-9

SW1-10

B122/B123

Off

Off

Off

Off

A132/A133

On

Off

Off

Off

B002/B003

Off

On

Off

Off

A002/A003

On

On

Off

Off

AFNOR NFS 87-500

Off

Off

On

Off

AFNOR NFS 87-500 ( DC )

On

Off

On

Off

The code AFNOR NFS 87-500 ( DC ) is the unmodulated version of the AFNOR code.
This unmodulated code is not standardized. The standard AFNOR-NFS 87-500 confi-
nes to the modulated signal.