Basic troubleshooting – Metro C5 3 Series Heated Cabinets User Manual

Page 13

Advertising
background image

11

baSIC TRoUbleSHooTInG

Module operation basics:

When the power switch is on, the blower is always energized, circulating air, and the digital thermometer is always

displaying the cabinet temperature. A thermostat controls whether an element will be energized depending on

the thermostat setting and the air temperature it is sensing. The control knob is used to change the thermostat

setting. When a thermostat senses the temperature has gone below its set point, the thermostat contacts close, the

appropriate indicator will light and the heater element will begin to produce heat. When the thermostat senses the

temperature has reached its set point, the contacts open, the indicator light will go out and the heater element will

stop producing heat.
Holding Module: The holding module has one heating element. It is in the air duct and heats up the air as it is

circulated in the cabinet. The thermostat senses the return air temperature and will energize the air duct element

as required to heat up the cabinet air. Some moisture can be introduced by filling the stainless steel water pan with

warm water and allowing the warm air to pick up the water vapor as the blower circulates the air. There is no heating

element to heat the water.
Moisture Holding and Proofing Module: There are two heating elements in these modules. One is in the air duct to

heat the air, and one is under the stainless steel water pan to heat the water and introduce moisture into the cabinet.

One thermostat senses the return air temperature and will energize the air duct element as required to heat up the

cabinet air. The other thermostat senses the air temperature around the water pan. It will energize the water pan

element to heat the water and release moisture into the cabinet.
Combination Proof and Hold Module: A combination proof and hold module has a mode switch, which allows the

module to act as either a holding module or a proofing module. Therefore, it has all the elements of both a holding

module and a proofing module. When the mode selector switch is set to HOLD, only the larger wattage air element is

used. The stainless steel water pan element is not used. When the mode selector switch is set to PROOF, the lower

wattage air element and the water pan element are used but independently controlled by individual thermostats. See

the appropriate paragraph above for more detail on how the Combination Proof and Hold Module operates in either

holding or proofing mode.
Element wattages are shown in the chart below:

20 amp, 2000 watt cabinet

15 amp, 1440 watt cabinet

Air Duct element

Water Pan element

Air Duct element Water Pan element

Combination module

1950 watt and 675 watt

675 watt

1360 watt and 675 watt

675 watt

Holding module

1950 watt

none

1360 watt

none

Proofing module

675 watt

675 watt

Moisture Holding module

1360 watt

590 watt

Element wattages are shown in the chart below:

220-240V, 1681-2000W cabinet

220-240V, 1210-1440W cabinet

Air Duct element

Water Pan element

Air Duct element Water Pan element

Combination module

1950 watt and 675 watt

675 watt

Holding module

1950 watt

none

Proofing module

675 watt

675 watt

Moisture Holding module

1360 watt

590 watt

Note: When heating element(s) are not energized, the amp draw for the blower and digital thermometer is

approximately 0.8 to 0.9 amps.

Warning: Only factory-approved service agents should attempt to service, repair or replace electrical

components, wiring or power cord..

1. Controls do not work (digital thermometer and indicator light(s) not lit):

a. Check that the cabinet is plugged in.

b. Check that the outlet has power. Is electrical service fuse blown or circuit breaker tripped?

c. Check that the power switch is in the “On” position.

d. Check the cabinet wiring from the power cord to the power switch and to the terminal block.

e. Power switch could be bad.

2. Temperature too hot:

a. Temperature set point is too high. Turn control knob down to a lower setting. Wait several minutes and see if

the displayed temperature decreases.

b. Thermostat may have failed with contacts closed. Check thermostat.

c. If displayed temperature exceeds 220°F (104°C):

22

0-

24

0V

12

0V

Advertising
This manual is related to the following products: