BASIC CABINET SETUP
A. Refer to DATA PLATE for electrical requirements. Cabinets rated at 120V 1440W must

be plugged into either a 15 amp or 20 amp 125VAC receptacle. Cabinets rated at 120V

2000W must be plugged into a 20 amp 125VAC receptacle. Cabinets rated at 220-

240V must be plugged into a 15 amp 250VAC receptacle.

B. With POWER switch OFF, plug into VAC grounded receptacle.
C. Fill stainless water pan to top with clean HOT tap water for Proofing or if moisture is

desired for Holding. Check water level every 3 hours (2 hours when Proofing) and

refill withclean HOT tap water as necessary. Water pan does not have to be filled for

Holding. Proofing requires water pan to be filled.

HOLDING INSTRUCTIONS (Holding, Combo, Moisture Holding)
1) Set Combination Module switch to HOLD.
2) Set POWER switch to the ON position.
3) Set TEMPERATURE control to 10.
4) Moisture Module Only: Set MOISTURE control to 10 (or desired level).
5) Pre-heat cabinet until desired temperature is reached (typical heat-up time

from72°(22°C)ambient to 160°(71°C)is approximately 45 minutes).

6) Re-set TEMPERATURE control and adjust as necessary to reach desired temperature -

setting 6-8 is typical for 150°(66°C) to 160° (71°C). Indicator light will turn on and off as

the heat thermostat cycles.

PROOFING INSTRUCTIONS (Combo and Proofing)
1) Set Combination Module switch to PROOF.
2) Set POWER switch to the ON position.
3) Set TEMPERATURE control to 2.
4) Set MOISTURE control to 10.
5) Pre-heat cabinet until desired temperature and humidity is reached (typical heat-up

time from 72°(22°C)ambient to 95°(35°C)and 95% relative humidity is approximately 30

minutes).

6) Adjust settings as necessary to reach desired temperature and humidity levels. Power

indicator lights will turn on and off as the heat and moisture thermostats cycle.

3 & 1 SERIES

STAINLESS WATER PAN MUST BE PLACED INSIDE CABINET DURING

MODULE OPERATION. PLASTIC DRIP PAN MUST BE PLACED UNDER THE

FRONT BUMPER DRIP TROUGH OF THE CABINET.

UNPLUG CABINET FROM WALL AND ALLOW CABINET (AND WATER) TO

COOL BEFORE CLEANING OR SERVICING.

DO NOT SPRAY OR POUR WATER ON THE MODULE WHEN CLEANING AND

DO NOT IMMERSE THE MODULE IN WATER. WIPE WITH A DAMP CLOTH

AND DRY WITH A TOWEL.

KEEP CABINET AND MODULE CLEAN. ACCUMULATION OF GREASE AND

OTHER DRIPPINGS MAY IGNITE.