Disable Tamper Evident Lockout Time:

Follow steps to enter Programming Mode (See
Section 5).

Enter 901.

Green Light Will Flash 4 Times.

Enter 0000 Seconds to disable lockout time

Green Light Will Flash 1 Time followed by a slight
delay.

Green Light will then flash 3 times, prompting user
to enter next location or exit programming mode
(See Section 6 for more detail).

Section 11: Auto Lock Time

– 902(Minutes) or

903 (Seconds)

If the Auto

Lock

feature is

used

,

the lock

will energize after

the set amount of

time

has expired and the spring

tension

in

the

cabinet mechanism will cause the handle to

return to

the

locked

position.

The

factory default Auto

Lock Time

is set

to

a

minutes.

The

auto

lock time is

measured in minutes (i.e.

10 minutes =

010, 2 hours

= 120

minutes) for 902 or

seconds for 903.


Change Auto Lock Time:

Follow steps to enter Programming Mode (See
Section 5).

Enter 902 or 903.

Green Light Will Flash 3 Times.

Enter 001 - 999 Minutes (or seconds) to set desired
auto lock time.

Green Light Will Flash 1 Time followed by a slight
delay.

Green Light will then flash 3 times, prompting user
to enter next location or to exit programming mode
(See Section 6).

Disable Auto Lock Feature:

Follow steps to enter Programming Mode (See
Section 5).

Enter 902 or 903.

Green Light Will Flash 3 Times.

Enter 000 Minutes or Seconds to disable auto lock
feature Green Light Will Flash 1 Time followed by a
slight delay.

Green Light will then flash 3 times, prompting user
to enter next programming location or to exit
programming mode (See Section 6 for more detail).

Section 12: Reset Parameters to Default
Settings

It

is possible

to reset

all parameters back

to

default settings

.

The user

can set

all parameters

excluding

user

codes back

to factory defaults. Likewise, the user can set all

parameters

including user codes back to factory defaults

,

consequently

de

l

eting all existing user codes

.

In

order to delete all

user

codes and reset all programmed

features

back to factory

defaults

,

cart must be in programming mode

.

Reset Default Settings Excluding User Codes:

Remove top drawer from cart.

Locate control board on inside of front of cart

There is a small pushbutton located on the bottom
of the control board (orange in color).

Ensure cart is not in programming mode (See
Section 5 for more detail on programming mode).

Push the button.

All settings (excluding user codes) are now
returned to factory defaults, including the
Supervisor Code which will now be 1234.

Reset Default Settings Including All User Codes:

Remove top drawer from cart.

Locate control board on inside of face of cart

There is a small pushbutton located on the bottom
of the control board (orange in color).

Ensure cart is in programming mode (See Section
5 for more detail on programming mode).

Push the button.

All settings are now returned to factory defaults,
including the Supervisor Code which will now be
1234.

Replace drawer.

Cart is ready to be used or programmed.

NOTE: If cart is not in programming mode, all
settings will be set back to defaults but all user
codes will not be deleted.

Proximity Reader Operating Instructions

The

cart comes

pre-programmed

with a Supervisor Code

of 1234. This

is the only code

that

is programmed into the

cart at time of delivery.

If

a

user

wishes

to open the

cart

before programming

any

other

codes

,

1234 must be

entered

.

Likewise,

if the

user

wishes to

begin

programming proximity cards (stickers

,

key fobs

,

etc)

into

open user slots

,

the pre-programmed Supervisor code

must be used

to

enter

programming

mode

.

See

Section 5

for

more detail on programming mode. See Section

13

on

how to program

proximity

cards into

user

slots

.

Section 13: Program & Delete User
Proximity Cards - 001 - 099

There

are

99

User slots in addition to the 1 slot

reserved

for the Supervisor

.

The User

slots are numbered

001

through 099

.

Program User Cards:

Follow steps to enter Programming Mode (See
Section 5).

Enter 001.

Green light Will Flash 4 Times.

Swipe Proximity Card.

Green light Will Flash 1 Time followed by a slight
delay.

3

Advertising