5. Periodic Inspection/Maintenance

5-10

5.5.8 Change air filter element

[Every 500 hours]




Air filter is an important part which is crucial to machine's performance and life.

Be sure to use genuine parts.

<Procedure>

After removing the cap“1”by loosening its latch

2”, clean its interior properly.

Remove the element “3”and then replace it with

a new one. (See 5.4)

When installing the cap“ 1” after replacing it,

properly push the element into the case“4”by
hand and then make sure that the hooks for fixing
the cap are surely set. Finally tighten it.

5.5.9 Clean of element in sedimenter

[Every 500 hours]

<Procedure>

Turn fuel selector valve“1”to“OFF”position.

Loosen the drain valve“2”and drain out condensed

water inside.

Turn the cup“3”to the left and remove it.

Be careful to remove the cup“3”because it is filled
with fuel. Wipe out split fuel completely.

Remove float“4”inside cup“3”

Washing element“5”and the cup inside with new

fuel.

Replace element“5”and O ring“6”,“7”if they are

found broken or damaged. (See 5.4)

After finishing clean, assemble it in reverse procedure.



If air is found still in fuel pipe, place starter switch

to“RUN”position and loosen air bleeding bolt“8”
to bleed air. After finishing air bleeding, tighten the
air bleeding bolt“8”.



Drain the condensate in container“9”,and then

dispose of condensate according to the designated
regulations.