Periodic inspection/maintenance – MMD Equipment 185S-5C2 part 2 User Manual

Page 15

Advertising
background image

5. Periodic Inspection/Maintenance

5-15

A100114

5.5.22 Check O-ring and Needle Valve of Auto-relief Valve and Vaccume relief valve

[3,000 hours or every 3 years ]



When reassembling, apply sufficient grease to O-ring Slot/O-ring and sliding surface.
Use CALTEX MULTIFAK EP1 grease or equivalent. Grease of poor quality will deteriorate the material.



Disassemble and clean the component,

and check O-ring“1”, “2”,“3”and
needle valve“4”. Then, replace O-ring
“

1”,

“

2”,

“

3” and rubber on the needle

valve“4”, if hardened.
(See 5.4)



Replacement of O-ring requires expert

technical knowledge.
So contact directly us or distributor.






5.5.23 Performance Check of Pressure Control Valve

[3,000 hours or every 3 years ]



When reassembling, apply sufficient grease to O-ring Slot/O-ring and sliding surface.

Use CALTEX MULTIFAK EP1 grease or equivalent. Grease of poor quality will deteriorate the material.

<Procedure>

①

When fully opening the air valves while the

machine is running, make sure that the
discharge pressure gauge shows the figure
between 49-68psi(3.4-4.7bar).

②

When the pressure is lower than 49psi( 3.4 bar) ,

replace spring“3” with a new one. (See 5.4)

③

When the indicator shows excessively higher

pressure, you will find that the piston does not
move smoothly due to foreign material and rust
stuck inside valve. In such a case, disassemble
the component for checking and cleaning.


1

2

3

4

1
2

3

4

A070339

1

2

3

4

1

2

3

4

Auto-relief valve

Vaccume relief valve

Advertising