5. Periodic Inspection/Maintenance

5-15


5.5.21 Check O-ring and Needle Valve of Auto-relief Valve and Vaccume

relief valve

[3,000 hours or every 3 years ]

Disassemble and clean the component,

and check O-ring“1”, “2”,“3”
and needle valve“4”. Then, replace
O-ring“1”,“2”,“3” and rubber
on the needle valve“4”, if hardened.

(See 5.4)






5.5.22 Performance Check of Pressure Control Valve

[3,000 hours or every 3 years ]

When reassembling, apply sufficient grease to O-ring Slot/O-ring and sliding surface.

Use CALTEX MULTIFAK EP1 grease or equivalent. Grease of poor quality will deteriorate the material.


<Procedure>

①

When closing stop valve and fully opening

service valve while the machine is running,
make sure that the discharge pressure gauge
shows the figure between 49-68psi
(3.4-4.7bar).

②

When the pressure is lower than 49psi( 3.4 bar) ,
replace spring“3” with a new one. (See 5.4)

③

When the indicator shows excessively higher
pressure, you will find that the piston does not
move smoothly due to foreign material and rust
stuck inside valve. In such a case, disassemble
the component for checking and cleaning.


1

2

3

4

A070338

1
2

3



4

A070339

1

2

3

4

1

2

3

4

Auto-relief valve

Vaccume relief valve

Advertising